800-654-0637
Register  or   Sign In
JLM Wholesale Technician Search
Cart
Picture of UL1812LTEGR
Call 800.654.0637 to Order
 
AMSEC’S UL Listed 2-Hour Fire & Impact Safes   
 
UL1812LTEGR
 
Outside Dimensions:  25” H x 18” W x 18-1/2” D (Add 2” to depth for handle)  
Inside Dimensions: 18-1/2” x 18-1/2” x 12”
Door Thickness: 3-1/2” thick recessed door with 5/8” thick front for pry resistance
Cubic In: 2,775
Weight: 272    
 
Fire & Impact Rating: UL 2 Hour
Lock: UL Listed Group II Key Changeable Combination Lock with relock.
Bolts: 2
Hardware: Chrome handle
Feet: 1” Rubber feet Safe
Color:  Textured Granite
Interior:  Plush Gray Velour with 1 Adjustable Shelf
Warranty:  Lifetime Fire Replacement and 1 Year Parts and Labor  
 
Features:
  • U.L. listed Class 350°F two hour fire and impact rating. Safes withstand fires of up to 1850°F for two hours and a 30' drop – equivalent to falling through a 2 story burning building.
  • U.L. Group II key changeable combination lock with relock.  1 million possible combinations.
  • Increased barriers for burglary protection.
  • Impressive 3½" thick recessed door with 5/8" thick front for excellent pry resistance.
  • Handle activated locking mechanism with 7/8" diameter solid steel chrome plated locking bolts offering smooth operation.
  • Internal anchor bolt hole with hardware.
  • Auxiliary spring-loaded relock device activated by severe attack.
  • Heavy duty steel hinges provide additional security and smooth operation.   
 
U.L. FIRE RESISTIVE RATING CLASSIFICATION THE FOLLOWING IS AN EXPLANATION OF THE UNDERWRITER’S LABORATORIES’ FIRE RESISTANT CONTAINER TESTING PROCEDURES ON THE CLASS 350°F, ONE HOUR AND TWO HOUR FIRE LABELS. U.L. Label/Class 350°F-one hour and Class 350°F-two hour. The safe will maintain an interior temperature less than 350°F when exposed to fire for a period of one hour at 1700°F or for a period of two hours at 1850°F. Safe must successfully undergo all other requirements for the Fire Endurance Test, Explosion Hazard Test and the Fire/Impact Test as stated below.
 
FIRE ENDURANCE TEST After heat sensors and paper are placed inside the safe, the unit is locked and exposed to a uniformly distributed fire. The furnace is regulated to reach a maximum temperature of 1700°F for a period of one hour, or 1850°F for two hours, then allowed to cool without opening the furnace. The interior temperature is recorded throughout the test and during the cooling period until a definite drop is shown and must never exceed 350°F. Once cooled, the unit is opened and examined for usability. The units locking mechanisms and parts fastenings are examined for security and the interior examined for visible evidence of undue heat transmission.
 
EXPLOSION HAZARD TEST The safe is locked and placed into a furnace preheated to 2000°F. This temperature is maintained for 30 minutes (2 hour test is 45 minutes) and if no explosion results, the unit is allowed to cool without opening the furnace doors. Once cooled, the unit is opened and examined for usability. The units locking mechanisms and parts fastenings are examined for security and the interior examined for visible evidence of undue heat transmission.
 
FIRE IMPACT TEST (MANUFACTURER’S OPTION) After the explosion hazard test the safe is removed from the furnace and within two minutes is dropped 30’ onto a riprap of brick on a heavy concrete base. After impact the unit is examined for deformation, rupture of parts, damaged insulation and any other openings into the interior of the unit. Once cooled, the unit is inverted and reheated to 1550°F for a period of 30 min. (2 hour test: 45 min. at 1638°F). Once cooled, the unit is opened and examined for usability. The units locking mechanisms and parts fastenings are examined for security and the interior examined for visible evidence of undue heat transmission.  
 
Options AMSEC ESL10XL electronic safe lock (Part No. UL1812E1LTEGR)
Lock Type Mechanical
Rating UL Fire Rating 2 Hour
Lock Type Mechanical
Rating UL Fire Rating 2 Hour

UL1812LTEGR

Details
SKU: UL1812LTEGR